Company in government tendersMSEMake in India Find a company
MAYA Engineering Works
Took part in 61 government tenders we have results for, the latest closing 13 Nov 2026. On record since Jan 2026. Bids most often for Indian Coast Guard.
See how MAYA Engineering Works bids before you bid against it, on the Business plan and up.
- Its wins, win rate and value won
- The prices it quoted, tender by tender
- The buyers and states it works in
- The rivals it meets most, and who wins
Business, ₹599 a month: 30 company profiles and the bids on 150 tenders a month. Complete: 300 and 1,000.
Tenders it took part in
The latest 20 of the 61 tenders it bid for. Who won and each price are in the full profile.
GEM/2026/B/8199573 · closed 13 Nov 2026
AC1,AC2,AC3,AC4,AC5,AC6,AC7Indian Coast GuardPrices opened
GEM/2026/B/8234392 · closed 10 Nov 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; L 066 02 nos emergency light fittings Make Rayen 20W 24V fitted at flydeck and Q deck are deteriorated Both emergency light fitting to be renewed as per samp..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; L 074 02 nos water tight DP switch socke Make Ajmera 15A 230V fitted at fly bridge are not working due to deterioration Switch socket to be replaced as per s..Indian Coast GuardPrices opened
GEM/2026/B/8199939 · closed 7 Nov 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS VIJIT; H-839 Gangway securing post at Quarter deck Stbd side deteriorated and MS channel with hinges uprooted to be renewed as per sample Channel size 25 x 65 cm th..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS VIJIT; H-841 Drain strainer Mat SS and flexible pipe Mat PVC of sink in Sick Bay deteriorated and strainer seal worn to be renewed as per sample; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS VIJIT; H-843 Securing clamp of vertical ladder on mast area deteriorated and affecting personnel safety Clamps with SS nuts 04 sets to be renewed as per sample Mat ..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS VIJIT; H-844 Operating handle Dia 45 cm Mat MS thickness 12 mm of ASP hatch deteriorated and material thinned down affecting personnel safety Operating handleIndian Coast GuardAwarded
GEM/2026/B/8199505 · closed 6 Nov 2026
AC1,AC2,AC3,AC4,AC5,AC6,AC7,AC8Indian Coast GuardPrices opened
GEM/2026/B/8168958 · closed 29 Oct 2026
AC1,AC2,AC3,AC4,AC5,AC6,AC7,AC8,AC9,AC10,AC11Indian Coast GuardAwarded
GEM/2026/B/8154550 · closed 26 Oct 2026
3 by 4 inch relief valve part no 4KHA3,Discharge pressure gauge part no 90261074 2 B,Suction pressure gauge part no 90261074 1 1,Angle valve size 5 by 8 inch part no PAL263909,Suction temp thermometer part No SA06P0004,Discharge temp thermometer part no SA06P0004,AHU V Belt part no A42,Drier FilterIndian Coast GuardAwarded
GEM/2026/B/8162789 · closed 23 Oct 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E075 Sea water leakage observed from exhaust pipe line of Port DA between exhaust flap valve and hull penetration area Leakage needs to be arrested by weldin..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E076 AC condenser safety valve discharge pipeline to be routed outside of compartment Qty02 nos Pipeline length 03 mtr All inway jobs included Mat Copper dia..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E077 01 in no fire hydrant dia 55 mm locking pin deteriorated Locking pin to be repaired renewed as per sample; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E078 Lub oil leakage observed from SME LO replenishment pump discharge pipeline near sump area Pipe dia 20 mm length 35 feet Mat MS Leakage needs to be arres..Indian Coast GuardAwarded
GEM/2026/B/8156141 · closed 20 Oct 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; H030 Firing ARC of 12 7 mm HMG and 7 62 mm LMG to be fabricated as per ships Gun firing limitation ARC; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; H031 Rubber beading of Ventilation Exhaust flaps 10, Doors 07 and Hatches 05 deteriorated Same to be renewed and proved for gas and water tight operations ap..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; H032 Wind sock securing post to be fabricated at foxle and proved for smooth operation Mat Aluminium size 2 ft Dia 25 mm; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; H033 Bed cushion securing arrangement to be fabricated Mat Nylon Velcro Double sided Dia 50 mm Approx Length 60 mtrs; Service ProviderIndian Coast GuardAwarded
GEM/2026/B/8137565 · closed 19 Oct 2026
Repair and Overhauling Service - Diesel Generators- Dg Sets (DFM); Repair and Overhauling of Hydraulic Power Pack; No; Buyer PremisesIndian Coast GuardAwarded
GEM/2026/B/8120884 · closed 19 Oct 2026
AC1,AC2,AC3,AC4,AC5,AC6,AC7,AC8,AC9,AC10,AC11Indian Coast GuardAwarded
GEM/2026/B/8084689 · closed 6 Oct 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E 061 Fire Bilge pump is not developing adequate pressure; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E 062 Port Main engine sea water pump vent pipeline corroded and is leaking from various places due to ageing; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E 063 Both DAs belt guard deterioarted New belt guard to be fabricated as per sample and fitted; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E 064 Sea water leakage obseved from SME exhaust pipeline in water jet compartment; Service ProviderIndian Coast GuardAwarded
GEM/2026/B/8080236 · closed 6 Oct 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-146; H-023 Defect rectification of water scooter cradle; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-146; H024 Defect rectification of guardrail; Service ProviderIndian Coast GuardAwarded
GEM/2026/B/8084037 · closed 3 Oct 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-146; E34 Emergency fire pump discharge hose coupling and suction hose with foot valve corroded and deteriorated Same to be repair/renewed as per sample Mat Plasti..Indian Coast GuardPrices opened
GEM/2026/B/8060818 · closed 1 Oct 2026
Plug in Board (CRB 1-03) , P/n: 5275302613Indian Coast GuardAwarded
GEM/2026/B/8069058 · closed 29 Sept 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E058 Flexible fuel hose of fuel system of both DA deteriorated Fuel hose needs to replace with adaptor as per sample Quantity 04 nos dia 18 mm length 1 6 mt..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E059 BME exhaust trunking aluminium cladding deformed and deteriorated Cladding needs to renew as per sample Dia 200 cm length 3 5 mtrs for each Main engine..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E060 Engine room lagging cloth deteriorated from various places Lagging cloths need to replace Total area 05 meter square; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; L046 02 nos ALDIS lamp fitted at flag deck are not working During DI DR following were observed 1 Nil output available of AC DC converter of both ALDIS lamp..,Repair,Indian Coast GuardPrices opened
GEM/2026/B/8056218 · closed 28 Sept 2026
Repair and Overhauling Service - Diesel Generators- Dg Sets (DFM); Repair on Stbd DA expansion tank; No; Buyer PremisesIndian Coast GuardAwarded
GEM/2026/B/7859534 · closed 11 Sept 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - Aux Barge Urja Sanchay; H 72 18 nos Tyre fenders holding chain with D shackles Chain length 500 mm Dia 16 mm Mat MS Qty 36 Nos observed to be corroded and thinned All ho..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - Aux Barge Urja Sanchay; H 73 Securing brackets for 03 nos lifebuoy corroded damaged and uprooted from base Brackets to be renewed as per sample and re welded Mat SS; Ser..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - Aux Barge Urja Sanchay; L 09 weather deck emergency light fittings 05 nos base deteriorated and glass broken Base to be fabricated and glass to renewed as per sample; Se..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - Aux Barge Urja Sanchay; L 10 Flood light securing bracket found corroded and damaged from base To be renewed as per sample Qty 04; Service Provider
Indian Coast GuardAwarded
GEM/2026/B/7976258 · closed 7 Sept 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-428; H 023 Hinges and locking arrangement of 12 in nos wooden locker broken same to be renewed and sun mica to be changed as per sample Hinges 24 nos Locks 12 nos..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-428; H 024 Firing ARC of 12 7 mm HMG and 7 62 mm LMG to be fabricated as per ships Gun firing limitation arc; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-428; H 025 Electroplating of ships commissioning board is deteriorated Same to be polished and renewed as per sample; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-428; H 026 Rubber beading of ventilation exhaust 04 deteriorated Same to be renewed and proved for gas tight operations Approx length 15 feet; Service Provider,Repair, Maintenance, and Installation of Plant/ Systems/Equip
Indian Coast GuardAwarded
GEM/2026/B/7969868 · closed 7 Sept 2026
Condenser safety valve,Gasket set complete,Valve plate assembly,Thermostat AHU unit,Switch Pressure,Terminal Assembly
Indian Coast GuardAwarded
GEM/2026/B/7844239 · closed 20 Aug 2026
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E047 Lagging top cover aluminum foil of engine room and water jet compartment approx area 10 sq mtr tear down Lagging top cover Aluminum foil to be renewed a..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E048 Fueling and defueling butter fly valve Size 50 DN at Stbd catwalk butter fly valves handle uprooted Valves handle to be renewed as per sample Mat SS; Se..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E049 OBM tank drain pipeline including valve uprooted and deteriorated Drain pipeline including valve to be replaced as per sample Pipeline length 05 feet Di..,Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-423; E050 Sea water leakage observed from various places of AC condenser pump no 2 discharged pipeline to condenser inlet view pipe line deteriorated Pip
Indian Coast GuardAwarded
Where these figures come from: Public results on GeM (gem.gov.in), 61 results for this company, last updated 20 Nov 2026. We match results to a company by its name, so two firms with the same name (in different towns, for example) show here as one.